Industrial interiors

LED high bay light: the roof decides the fixture

A high bay is chosen by mounting height and by what sits under it: racking, machines, a production line or a loading bay. The roof structure usually rules out more options than the photometry does.

Product lineOUTDOOR LIGHTING SUPPLY
UGR 22Glare limit, EN 12464
0.6Aisle uniformity
2Beam families
6 to 15 mTypical mounting
Round industrial high bay luminaire with a finned heat sink and a visible LED array
The high bay form: a heat sink, a lens and a hook, sized by the roof

Height above the floor decides the optic, the aisle grid decides the rows, and the roof decides how the unit is fixed. The fixture itself is the result of those three.

Interior against fixture

The same hall can need two different fixtures once the racking goes in. The table is the short version of the survey.

High bay choice by interior
InteriorWhat is litBeamWhat decides it
Warehouse, rackedRacking faces and aisle floorNarrow to medium, aimed down the aisleAisle width against racking height
Warehouse, open floorFloor and packing benchesWide, symmetricRoof height and truss spacing
Factory hallMachine beds, benches, walkwaysWide with a higher glare classTask level and the sight line
Loading bayTrailer beds and apronAsymmetric, aimed outDoor height and the apron depth

An aisle that is lit from directly above shows a bright stripe on the floor and dark racking faces. Moving the row over the aisle, or widening the optic, is usually the fix, and it is a layout change rather than a fixture change.

The three numbers that decide it

Mounting height, aisle geometry and the task at eye level. Everything else in a high bay quotation is downstream of those three. Height sets the optic and the number of rows; geometry sets whether the beam runs down an aisle or spreads across a floor; the task decides the colour rendering and the glare class.

A retrofit adds a fourth: the existing roof. Purlins, trusses, sprinkler runs and ductwork decide the fixing, the suspension length and sometimes whether a high bay fits at all. The survey that matters is a photograph of the roof, not a floor plan.

Mounting height
Measured to the light emitting face, not to the roof
Rows
Set by the aisle grid, not by the roof bays
Uniformity
Aisle floor and racking face read differently
Glare
UGR limit where people look up at the fixtures
Colour
Higher rendering where colour is inspected
Fixing
Chain, hook, bracket or direct to purlin
Control
Occupancy and daylight where the hall allows
Access
How a unit is reached without a scaffold

What a retrofit has to answer

A replacement is a survey before it is a quotation.

A retrofit that keeps the old fixing points and the old rows is usually the cheapest and the least disruptive. A retrofit that re-plans the rows costs more in labour than in hardware, so it needs a photometric case, not a preference.

Why no wattage on this page

The same hall can be lit at the required level by very different fixture counts, depending on the optic, the mounting height and the maintenance factor the designer applies. Publishing a wattage would suggest that the wattage is the answer, and it is the last variable rather than the first.

What we publish is the method: the level the task needs, the uniformity beside it, the glare limit, and the geometry. The fixture that satisfies those is confirmed against a photometric file for the exact model.

Given by the project
Level, uniformity, glare class, colour
Given by the building
Height, rows, fixings, supply
Given by us
Optic, housing, control gear, documents
Always asked for
IES file for the exact model

Before the order

The four things a high bay quotation gets wrong most often.

  • Height to the emitting face, not to the roof deck. Half a metre changes the optic.
  • Aisle against floor: state which one the fixture has to light. They want different beams, and one fixture rarely does both well.
  • The fixing: purlin, truss, chain or bracket. It is a line item and it is often left out of the comparison.
  • Control: occupancy sensing in a racked aisle saves energy and annoys pickers if the sensor sees the wrong zone.
Interiors
Warehouse, factory, loading bay
Beams
Narrow aisle and wide floor
Mounting
Chain, hook, bracket, purlin
Ask for
IES file, fixing detail, control options

Send the space, the standard and the mount.

What is being lit, to what requirement, mounted where, and what power is available is enough. The reply is a build, a specification sheet and the option list for each line item.